ÏêÇé½éÉÜ£º

¹àעϵͳ¸ÅÊö

HSEHAÉúÀíѧϵͳÊÇһϵÁÐÓ¦Óù㷺µÄÍ걸²úÆ·£¬¿ÉÓÃÓÚÕûÌ嶯ÎïÉúÀíѧ¡¢Á¢Ìå»òÔÚÌåÆ÷¹ÙºÍ×éÖ¯¹à×¢¼°×éÖ¯Ô¡²ÛÑо¿¡£ÕâЩϵͳ¾ßÓй㷺µÄÓ¦Ó㬰üÀ¨´«Í³µÄ**Ò©Àíѧ¡¢DMPK¡¢¶¾Àíѧ¡¢ºôÎüϵͳ¡¢ÐÄÔಡѧ¡¢·Ö×ÓÉúÎïѧºÍÉúÀíѧ¡£Ã¿¸öϵͳ¶¼Éè¼ÆÁ˱ê×¼µÄ×é¼þ£¬ÔÙ¼ÓһЩÆäËûÅäÖÃÒÔÊʺÏÌØÊâÑо¿µÄÐèÒª¡£¡£±ê×¢×é¼þÒ²Òâζ×ÅÈç¹ûÄãÊÇÐèÒª½«ÏÖÓÐÉ豸ÅäÆ룬»òÕß½øÐÐϵͳÉý¼¶£¬»òÕßÊÇÍêÕûµÄÅäÌײúÆ·£¬Ä㶼ֻÐèÒª¹ºÂòÐèÒªµÄ¹¹¼þ¡£HSE-HAÉúÀíѧϵͳΪÄãÌṩ¸÷ÖÖ¹¤¾ß£¬Ê¹ÄãµÄÑо¿×ßÏò¶à²úºÍ³É¹¦¡£

¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´Ìṩ´ó¶àÊýÉúÀíѧ¼ì²âÉ豸£¬°üÀ¨·Å´óÆ÷¡¢µç¼«¡¢´«¸ÐÆ÷ºÍµç»¯Ñ§¼ì²âÆ÷¡£²ÎÊý°üÀ¨Á¦¡¢Î»ÒÆ¡¢Ñ¹Á¦¡¢ÒºÌåºÍÆøÌåÁ÷¡¢Ðĵçͼ£¨µ¥µ¼Áª—12µ¼ÁªÏµÍ³£©¡¢MAP£¨µ¥¸ö»ò¶à¸ö²¿Î»£©¡¢ÄÔµçͼ¡¢¼¡µçͼ¡¢Á¬ÐøÖ§Á÷¹à×¢´«Í³µÄѪÆø²ÎÊýºÍµç½âÖʵķÖÎö£¬¿ÉÒÔÑ¡Ôñ³ÌÐò»¯Èí¼þºÍ´«Í³µÄ´Ì¼¤Æ÷×÷Ϊ·Å´óÆ÷¡¢µç¼«ºÍ´«¸ÐÆ÷µÈ²úÆ·µÄ²¹³ä¡£

HSE-DAQϵͳ²úÆ·¼Ò×壨BDAS¡¢ACAD¡¢HAEMODYN¡¢ISOHEART¡¢PULMODYN¡¢PENNOCK£©¿ÉÒԼǼÄãµÄ³õʼÐźÅ£¬¼ÆËãµ½´¦µÄ²ÎÊý£¬×¢ÊÍÊý¾Ý£¬¿ìËÙ¼òÒ×µÄÊäÈëÈ·¶¨µÄÊý¾ÝÓÃÓÚ·ÖÎö¡£Í¬Ê±»¹¿ÉÒÔÑ¡ÔñÓÃÓÚ½øÒ»²½·ÖÎöµÄÈí¼þÄ£¿é£¬´ø×´¼Ç¼ֽ´òÓ¡£¬×Ô¶¯ºÍ¿ØÖÆÄ£¿éµÈ¡£²úÆ·¾­¹ýÔ¤ÏÈÉèÖ㬴ò¿ª°ü×°¼´¿ÉʹÓ㬲¢×¨ÃÅÉè¼Æ·ûºÏÄãµÄϵͳÅäÖúÍÊý¾Ý·ÖÎöÒªÇó¡£

 

The Isolated Heart Size 5, IH-5, apparatus permits the use of hearts of small animals (rodents) as well as larger animals like rabbits. The flow limitation is about 500 ml/min. The perfusate is oxygenated in a 6 liter water jacketed reservoir with multiple ports for recirculation of the perfusate.

The system can be used for work in any one of three methods. The basic system is the retrograde perfusion mode (Langendorff). By setting a defined threshold pressure at the flow resistance, the system works under constant pressure; by increasing the threshold pressure to a supermaximal pressure (300 mmHg) the system works under constant flow. A working heart system can be arranged by using the Left Atrium Cannulating Option. The complete system is mounted on a compact acrylic stand.

The system can also be used to simultaneously record all hemodynamic parameters as well as 8 AP-potentials and a 12-lead ECG. For this purpose, the IH-5 unit is additionally equipped with a circular holder for 8 MAP-electrodes and with an ECG multi-electrode insert in the heart chamber.

• High perfusion pressure (up to 300 mmHg); easy and fast changes of the perfusion pressure (within seconds)

• Continuous measurement of heart mechanics (contractility, segment lengths), bioelectrical signals (ECG, MAP) and perfusate characteristics (pCO2, pO2, pH)

• The system can easily be modified to a working heart system, the special flow resistance and compliance chamber mimics closely the in-vivo afterload

• Multiple monophasic action potentials (MAP) and simultaneous multilead ECG recording from Isolated Perfused Rabbit heart

• Extended system for hemodynamic and electrophysiology studies

• Applications:– Dispersion of ventricular repolarization