¼òµ¥½éÉÜ£º
ÓÃÓÚÖíµÄÀëÌå¸ÎÔà»òÉöÔàµÄ¹àעϵͳ
ÏêÇé½éÉÜ£º

¹àעϵͳ¸ÅÊö

HSEHAÉúÀíѧϵͳÊÇһϵÁÐÓ¦Óù㷺µÄÍ걸²úÆ·£¬¿ÉÓÃÓÚÕûÌ嶯ÎïÉúÀíѧ¡¢Á¢Ìå»òÔÚÌåÆ÷¹ÙºÍ×éÖ¯¹à×¢¼°×éÖ¯Ô¡²ÛÑо¿¡£ÕâЩϵͳ¾ßÓй㷺µÄÓ¦Ó㬰üÀ¨´«Í³µÄ**Ò©Àíѧ¡¢DMPK¡¢¶¾Àíѧ¡¢ºôÎüϵͳ¡¢ÐÄÔಡѧ¡¢·Ö×ÓÉúÎïѧºÍÉúÀíѧ¡£Ã¿¸öϵͳ¶¼Éè¼ÆÁ˱ê×¼µÄ×é¼þ£¬ÔÙ¼ÓһЩÆäËûÅäÖÃÒÔÊʺÏÌØÊâÑо¿µÄÐèÒª¡£¡£±ê×¢×é¼þÒ²Òâζ×ÅÈç¹ûÄãÊÇÐèÒª½«ÏÖÓÐÉ豸äÆ룬»òÕß½øÐÐϵͳÉý¼¶£¬»òÕßÊÇÍêÕûµÄÅäÌײúÆ·£¬Ä㶼ֻÐèÒª¹ºÂòÐèÒªµÄ¹¹¼þ¡?/SPAN>HSE-HAÉúÀíѧϵͳΪÄãÌṩ¸÷ÖÖ¹¤¾ß£¬Ê¹ÄãµÄÑо¿×ßÏò¶à²úºÍ³É¹¦¡£

¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´Ìṩ´ó¶àÊýÉúÀíѧ¼ì²âÉ豸£¬°üÀ¨·Å´óÆ÷¡¢µç¼«¡¢´«¸ÐÆ÷ºÍµç»¯Ñ§¼ì²âÆ÷¡£²ÎÊý°üÀ¨Á¦¡¢Î»ÒÆ¡¢Ñ¹Á¦¡¢ÒºÌåºÍÆøÌåÁ÷¡¢Ðĵçͼ£¨µ¥µ¼Áª—12µ¼ÁªÏµÍ³£©¡¢MAP£¨µ¥¸ö»ò¶à¸ö²¿Î»£©¡¢ÄÔµçͼ¡¢¼¡µçͼ¡¢Á¬ÐøÖ§Á÷¹à×¢´«Í³µÄѪÆø²ÎÊýºÍµç½âÖʵķÖÎö£¬¿ÉÒÔÑ¡Ôñ³ÌÐò»¯Èí¼þºÍ´«Í³µÄ´Ì¼¤Æ÷×÷Ϊ·Å´óÆ÷¡¢µç¼«ºÍ´«¸ÐÆ÷µÈ²úÆ·µÄ²¹³ä¡£

HSE-DAQϵͳ²úÆ·¼Ò×壨BDAS¡¢ACAD¡¢HAEMODYN¡¢ISOHEART¡¢PULMODYN¡¢PENNOCK£©¿ÉÒԼǼÄãµÄ³õʼÐźÅ£¬¼ÆËãµ½´¦µÄ²ÎÊý£¬×¢ÊÍÊý¾Ý£¬¿ìËÙ¼òÒ×µÄÊäÈëÈ·¶¨µÄÊý¾ÝÓÃÓÚ·ÖÎö¡£Í¬Ê±»¹¿ÉÒÔÑ¡ÔñÓÃÓÚ½øÒ»²½·ÖÎöµÄÈí¼þÄ£¿é£¬´ø×´¼Ç¼ֽ´òÓ¡£¬×Ô¶¯ºÍ¿ØÖÆÄ£¿éµÈ¡£²úÆ·¾­¹ýÔ¤ÏÈÉèÖ㬴ò¿ª°ü×°¼´¿ÉʹÓ㬲¢×¨ÃÅÉè¼Æ·ûºÏÄãµÄϵͳÅäÖúÍÊý¾Ý·ÖÎöÒªÇó¡£

 

• For use in physiological or pharmacological research for the perfusion of a pig liver or kidney with blood or erythrocyte containing perfusate

 

Basic System

The pig liver to be perfused is placed in a moist, thermostated chamber and perfused with blood through the portal vein under constant-flow conditions. A centrifugal pump with a gentle action on blood is employed to reduce hemolysis; it is controlled by an electronic controller (SCP) so that the apparatus can be operated under constant-flow conditions. The system can also operate under constant-pressure conditions. Flow control requires that the flow is measured by means of a flow probe (16N) and a flowmeter (TTFM).

The pressure should also be measured to monitor the experiment. This requires a pressure transducer (P75) and a bridge amplifier (TAM). A suitable oxygenator is employed for oxygenating and warming the blood; it can be of a type used in human medicine, e.g. Terumo Capiox SX10®.

Components required

The following items are required for operating the apparatus:

• Thermostated moist chamber Type 869/2

• Circulating thermostat of approx. 3 liter capacity, distilled water and an anti-algal agent, e.g. Thermoklar

• Pump with electrical control. For blood we recommend a Pump Drive BVP-ZX with centrifugal pump head, see the Pump Section A

• Servo Controller for Perfusion (SCP) Type 704, see page K12

• Flowmeter (TTFM) with flow probe (16N), see pages J6 and J7

• Recommended: pressure transducer (P75), see page J3 and bridge amplifier (TAM-D), Section I of this Catalog

• Oxygenator with heat exchanger, e.g. Terumo Capiox SX10®

• Source of Carbogen for aeration. Central supply or Carbogen cylinder with pressure reducing valve

Additional monitoring equipment can be added to the system as required to create a custom, application specific, turn key system for your unique research needs.

 