553333
|
Harvard 33 Twin Syringe Pump
|
¼¼Êõ²ÎÊý
|
553333
|
|
ÀàÐÍ
|
´ø΢´¦ÀíÆ÷µÄË«Çý¶¯µ¥×¢ÉäÆ÷×¢Éä/»Ø³é
|
±Ã½á¹¹
|
±ê×¼
|
±Ã¹¦ÄÜ
|
×¢Éä/»Ø³é
|
*СÁ÷ËÙ
|
0.0004 µl/hr
|
*´óÁ÷ËÙ
|
106.6 ml/min
|
×¢ÉäÆ÷ÊýÁ¿
|
2
|
×¢ÉäÆ÷¼ÜÀàÐÍ
|
±ê×¼Ö§¼Ü
|
×¢ÉäÆ÷*С³ß´ç
|
0.5 µl
|
×¢ÉäÆ÷*´ó³ß´ç
|
140 ml
|
ƽ¾ùÖ±ÏßÍÆÁ¦
|
57 lbs
|
ѹÁ¦
|
±ê×¼
|
ͨÐŵȼ¶
|
2
|
ͨÐÅ
|
RS-232, TTL
|
**¶È
|
0.35 %
|
¸´ÏÖÐÔ
|
0.1 %
|
·ÇÒ×ʧÐÔ´æ´¢Æ÷
|
´æ´¢ËùÒÔÉèÖÃ
|
RS-232
|
RJ11-4 Á¬½ÓÍ·
|
TTL
|
9-pinÁ¬½ÓÍ·
|
Âí´ï
|
Á½¸öµç»ú£¬´Ó1/2µ½1/4 ΢²½²½½ø£¬Ã¿¸öΪ0.9 ? ²½½Ç²½½øµç»ú
|
µ¼ÏòÂݸËÿתһȦµç»úÇ°»ú²½Êý
|
1,600 at 1/2 stepping; 3,200 at 1/4 stepping
|
*С²½ËÙ
|
27.3 sec/step
|
*´ó²½ËÙ
|
416.7 µsec/step
|
²½·Ö±æÂÊ
|
0.33 µm/step
|
ÍƽøÆ÷Òƶ¯*СËÙ¶È
|
0.726699 µm/min
|
ÍƽøÆ÷Òƶ¯*´óËÙ¶È
|
95.25 mm/min
|
ÏÔʾ
|
LED, 5 digit, numeric
|
ÊäÈ빦ÂÊ
|
1.0 A, 45 W
|
µçѹ·¶Î§
|
Selectable, 95 to 130 VAC, 60 Hz or 220 to 260 VAC, 50 Hz
|
¸ß¶È
|
15.2 cm
|
¿í¶È
|
31.1 cm
|
Éî¶È
|
28.6 cm
|
¾»ÖØ
|
6.8 kg
|
The Harvard 33 Dual Syringe Pump offers continuous infusion or withdrawal, 24 hours a day, 365 days a year with the accuracy and low flow of a Harvard syringe pump.
The Harvard 33 Dual Syringe Pump is a breakthrough in pumping technology. The 33 has two independent pumping channels linked through hardware and software. When combined with a valve box, it provides the continuous delivery of a peristaltic or piston pump with the accuracy, absence of pulsation and low flow rates of a syringe pump.
The Harvard 33 Dual Syringe Pump opens up whole new pumping possibilities.
These are some of the applications of this pump:
• The injection of dyes, perfumes and flavoring in industrial applications
• Applications with liquids or viscous materials in micromanufacturing
• Continuous injections of reactants into reactor vessels
• Simultaneous samplings from two sites
• Continuous injection for long term toxicology testing
Several modes of operation are available to accommodate a range of setups and experimental protocols. A unique movable limit switch mechanism is used to change direction or stop operation of the pump depending on the mode of operation.
Reciprocal/Parallel Mode - Syringe mechanisms can run in the same or opposite directions (i.e. both infusing/withdrawing at the same time or one infusing and the other withdrawing)
Proportional Mode - Different flow rates and syringe diameters can be set for each syringe mechanism
AutoStop Mode - Pump stops operation when a limit switch is activated.
Continuous Run Mode - When a limit switch is activated each syringe mechanism reverses direction.
The pump has high pressure capability and TTL and RS-232 interface for data acquisition and control.
The communication ports enable daisy-chaining of up to 100 pumps.
¼¼Êõ²ÎÊý |
|
ÀàÐÍ |
´ø΢´¦ÀíÆ÷µÄË«Çý¶¯µ¥×¢ÉäÆ÷×¢Éä/³éÎüÐÍ |
Îȶ¨¾«¶È |
± 0.35% |
¸´ÏÖ¾«¶È |
± 0.1% |
×¢ÉäÆ÷³ß´ç£º |
|
*С |
0.5 μl |
*´ó |
140 ml |
Á÷ËÙ£º |
|
*С |
0.0004μl / hr |
*´ó |
106.6 ml / min |
·ÇÒ×ʧÐÔ´æ´¢Æ÷ |
´æ´¢ËùÓÐÉèÖà |
RS – 232 |
RJ11 - 4²åÍ· |
TTL |
9 - Õë²åÍ· |
ƽ¾ùÖ±ÏßÍÆÁ¦ |
|
Çý¶¯µç»ú |
Á½¸öµç»ú£¬Ã¿¸öΪ0.9 ? ²½½Ç²½½øµç»ú |
µç»úÇý¶¯¿ØÖÆ |
´Ó1/2µ½1/4 ΢²½²½½ø¿ÉÒÔ½øÐÐ΢´¦ÀíÆ÷¿ØÖÆ |
µ¼ÏòÂݸËÿתһȦµç»úÇ°»ú²½Êý |
ÔÚ1/2 ²½½øʱ1600»òÕßÔÚ1/4 ²½½øʱ3200 |
²½ËÙ£º |
|
*С |
27.3Ãë/²½ |
*´ó |
416.7΢Ãë/²½ |
ÍƽøÆ÷Òƶ¯Ëٶȣº |
|
*С |
0.726699 μm / min |
*´ó |
|
¹¦ÂÊ |
45 W, |
µçѹ·¶Î§ |
95µ½130V½»Á÷, 60Hz, 220µ½260V½»Á÷, 50Hz, ¿ÉÑ¡ |
³ß´ç, ¸ß x ¿í x ³¤ |
15.2 x 31.1 x |
ÖØÁ¿ |
|
Æ·ÖʳÐŵ
|
ÔËËÍ˵Ã÷
|
ÊÛºó·þÎñ
|
·þÎñÀíÄî
|
ÁªÏµ¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´
|
ʵÎïÅÄÕÕÁ¦ÇóÕæʵ
È«ÐÂÔ³§**½ø¿Ú ²úÆ·¹¦ÄÜÈçʵÃèÊö |
¹ú¼Êרҵ»õÔË¿ìµÝ·þÎñ
Ô˱£·ÑÈçʵÊÕÈ¡¼«ÓÅ»Ý »õÆڶ̰ü×°ºñʵ¼«** |
רҵ¹¤³ÌʦÉÏÃÅ°²×°
Ò¼ÄêÈ«Ãâ·Ñ±£ÐÞ·þÎñ 365ÌìÉÏÃÅÅàѵ·þÎñ |
·þÎñרҵ¡¢ÒµÎñºñµÀ
×ðÖØ¿Í»§¡¢Àí½â¿Í»§ ÖµµÃÄúÐÅÀµµÄ·þÎñÉÌ |
µç»°£º010-51650521
´«Õ棺010-51650521 Óʼþ:info@naturegene.com |
010-51650520
info@naturegene.com