HSEHAÉúÀíѧϵͳÊÇһϵÁÐÓ¦Óù㷺µÄÍ걸²úÆ·£¬¿ÉÓÃÓÚÕûÌ嶯ÎïÉúÀíѧ¡¢Á¢Ìå»òÔÚÌåÆ÷¹ÙºÍ×éÖ¯¹à×¢¼°×éÖ¯Ô¡²ÛÑо¿¡£ÕâЩϵͳ¾ßÓй㷺µÄÓ¦Ó㬰üÀ¨´«Í³µÄ**Ò©Àíѧ¡¢DMPK¡¢¶¾Àíѧ¡¢ºôÎüϵͳ¡¢ÐÄÔಡѧ¡¢·Ö×ÓÉúÎïѧºÍÉúÀíѧ¡£Ã¿¸öϵͳ¶¼Éè¼ÆÁ˱ê×¼µÄ×é¼þ£¬ÔÙ¼ÓһЩÆäËûÅäÖÃÒÔÊʺÏÌØÊâÑо¿µÄÐèÒª¡£¡£±ê×¢×é¼þÒ²Òâζ×ÅÈç¹ûÄãÊÇÐèÒª½«ÏÖÓÐÉ豸ÅäÆ룬»òÕß½øÐÐϵͳÉý¼¶£¬»òÕßÊÇÍêÕûµÄÅäÌײúÆ·£¬Ä㶼ֻÐèÒª¹ºÂòÐèÒªµÄ¹¹¼þ¡£HSE-HAÉúÀíѧϵͳΪÄãÌṩ¸÷ÖÖ¹¤¾ß£¬Ê¹ÄãµÄÑо¿×ßÏò¶à²úºÍ³É¹¦¡£

¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´Ìṩ´ó¶àÊýÉúÀíѧ¼ì²âÉ豸£¬°üÀ¨·Å´óÆ÷¡¢µç¼«¡¢´«¸ÐÆ÷ºÍµç»¯Ñ§¼ì²âÆ÷¡£²ÎÊý°üÀ¨Á¦¡¢Î»ÒÆ¡¢Ñ¹Á¦¡¢ÒºÌåºÍÆøÌåÁ÷¡¢Ðĵçͼ£¨µ¥µ¼Áª—12µ¼ÁªÏµÍ³£©¡¢MAP£¨µ¥¸ö»ò¶à¸ö²¿Î»£©¡¢ÄÔµçͼ¡¢¼¡µçͼ¡¢Á¬ÐøÖ§Á÷¹à×¢´«Í³µÄѪÆø²ÎÊýºÍµç½âÖʵķÖÎö£¬¿ÉÒÔÑ¡Ôñ³ÌÐò»¯Èí¼þºÍ´«Í³µÄ´Ì¼¤Æ÷×÷Ϊ·Å´óÆ÷¡¢µç¼«ºÍ´«¸ÐÆ÷µÈ²úÆ·µÄ²¹³ä¡£

HSE-DAQϵͳ²úÆ·¼Ò×壨BDAS¡¢ACAD¡¢HAEMODYN¡¢ISOHEART¡¢PULMODYN¡¢PENNOCK£©¿ÉÒԼǼÄãµÄ³õʼÐźÅ£¬¼ÆËãµ½´¦µÄ²ÎÊý£¬×¢ÊÍÊý¾Ý£¬¿ìËÙ¼òÒ×µÄÊäÈëÈ·¶¨µÄÊý¾ÝÓÃÓÚ·ÖÎö¡£Í¬Ê±»¹¿ÉÒÔÑ¡ÔñÓÃÓÚ½øÒ»²½·ÖÎöµÄÈí¼þÄ£¿é£¬´ø×´¼Ç¼ֽ´òÓ¡£¬×Ô¶¯ºÍ¿ØÖÆÄ£¿éµÈ¡£²úÆ·¾­¹ýÔ¤ÏÈÉèÖ㬴ò¿ª°ü×°¼´¿ÉʹÓ㬲¢×¨ÃÅÉè¼Æ·ûºÏÄãµÄϵͳÅäÖúÍÊý¾Ý·ÖÎöÒªÇó¡£

• Complete perfusion system ready for use for liver, kidney, etc.

• Compact arrangement

• Organ is in warm and moist environment during perfusion

• Optimized temperature control of perfusate and organ

• Perfusion can be performed at constant pressure or constant flow without involving any modification of apparatus

• Perfusion pressure can be set up to 300 mmHg by means of rotary control

• Perfusion flow range up to approximately 60 ml/min

 

The PS-1 system is an optimized version of the UP-100 when only ex vivo perfusion using a moist chamber is required. The organ is located in a moist chamber during perfusion, a warm and moist atmosphere. The moist chamber can be equipped with bubble traps and flow probes directly at the entry of the organ. Perfusion is possible either under constant pressure or under constant flow conditions. Additional items are available to suit the scope of the intended experiments. These items include:

• Air vessel for reducing the pulsation produced by the roller pump

• Pressure measuring system for evaluating the exact perfusion pressure

• Flow measuring system for evaluating the flow during experiments under constant pressure conditions

• Measuring system for continually evaluating the partial oxygen pressure in the perfusate, for determining oxygen consumption Applications for ex vivo perfusion using a moist chamber of liver, kidney, mesenteric bed...

• Test of vasodilative drugs

• Studying metabolic processes

• Neural vascular tone

• Organ preservation for transplant