²úÆ·ÏêÇé
  • Ãû³Æ£º¾«ÃÜ×¢Éä±Ã

  • ÐͺţºPHD 4400³¬¸ßѹ¿É±à³Ì
  • ³§ÉÌ£ºHarvard Apparatus
  • Îĵµ£º
ÄãÌí¼ÓÁË1¼þÉÌÆ· ²é¿´¹ºÎï³µ
¼òµ¥½éÉÜ£º
PHD 4400 Hpsi³¬¸ßѹ¿É±à³Ì¾«ÃÜ×¢Éä±ÃÊǵ¥×¢ÉäÆ÷×¢Éä/»Ø³é¾ßÓÐPHD 22/2000ϵÁÐÐͺÅËùÓеŦÄÜ¡£µ«ÊǾßÓдó¹¦ÂʵIJ½½øÂí´ïÌṩÏ൱ÓÚ200°õµÄÖ±ÏßÍÆÁ¦¡£4400 Hpsi³¬¸ßѹ¿É±à³Ì¾«ÃÜ×¢Éä±Ã¿ÉÊäËÍÏ൱ÓÚ220.82ºÁÉý/·ÖÖÓÀûÓÃ140ºÁÉýµ¥×¢ÉäÆ÷¡£*´óѹÁ¦ÒÀÀµÓÚ×¢ÉäÆ÷³ß´ç¡£ÓÃÓÚ²»Ðâ¸Ö×¢ÉäÆ÷¡£Harvard×¢Éä±ÃÒÔ³öÉ«µÄ¿É¿¿ÐÔ¶øÏíÓþÊÀ½ç£¬ÇëÓë¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´¿Æ¼¼¾­³§¼ÒÅàѵµÄ¼¼Êõר¼ÒÁªÏµ
ÏêÇé½éÉÜ£º

 

¹þ·ðPHD 4400 Hpsi ³¬¸ßѹ¿É±à³Ì¾«ÃÜ×¢Éä±Ã
±ê×¼×¢Éä/»Ø³é

 


씀²úÆ·ÃèÊö
702200
PHD 4400 Hpsi Programmable Syringe Pump
³¬¸ßѹ¿É±à³Ì¾«ÃÜ×¢Éä±Ã

 

l   ÔڽϹãµÄÁ÷ËÙ·¶Î§ÄÚ¾ù¿ÉʵÏÖÊäעѹÁ¦ > 200 lbs (91kg) µÄÏßÐÔÊä×¢
l   **¶øÇÒÎȶ¨µÄÒºÁ÷
l   ¶Ô²»Ðâ¸Ö×¢ÉäÆ÷µÄÊÊÓÃÐԷdz£ÀíÏë
l   ±ãÓÚʹÓõĽӿÚ
l   ͨ¹ý´®ÐнӿڴÓÄúµÄPCÉϽøÐпØÖÆ
l   Á½ÄêÖʱ£
 
PHD 4400 Hpsi ³¬¸ßѹ¿É±à³Ì¾«ÃÜ×¢Éä±ÃÊǵ¥×¢ÉäÆ÷×¢Éä/»Ø³é£¬¾ßÓÐPHD 22/2000ϵÁÐÐͺÅËùÓеŦÄÜ¡£µ«ÊǾßÓдó¹¦ÂʵIJ½½øÂí´ïÌṩÏ൱ÓÚ200°õµÄÖ±ÏßÍÆÁ¦¡£

ѹÁ¦ºÍËٶȡ£
PHD 4400 Hpsi³¬¸ßѹ¿É±à³Ì¾«ÃÜ×¢Éä±Ã¿ÉÊäËÍÏ൱ÓÚ220.82ºÁÉý/·ÖÖÓÀûÓÃ140ºÁÉýµ¥×¢ÉäÆ÷¡£*´óѹÁ¦ÒÀÀµÓÚ×¢ÉäÆ÷³ß´ç¡£ÓÃÓÚ²»Ðâ¸Ö×¢ÉäÆ÷¡£
 
Áé»îÐÔºÍÈÝÒ×±à³Ì
Á½¸ö±ê×¼×¢Éäģʽ£¨Á¬Ðø»òÕßÌå»ý·ÖÅ䣩
ËùÓÐÐͺÅÄÚ²¿¿É±à³Ì±Ã¿ØÖÆ
³ÌÐòÐͺŸ´ÔÓµÄ×¢É䣬Í˳öÓ¦ÓóÌÐò¿ÉÒÔºÜÈÝÒ׵ش´½¨£¬´æ´¢ÔÚ·ÇÒ×ʧÐÔÄÚ´æºÍ±ÃÒÔºóʹÓÃÕٻء£
×Ô¶¯Ìî³äģʽÌṩÁ¬ÐøÊäËÍʱ±Ã½áºÏʹÓÃÒ»¸ö±ê×¼»ò¸ßѹ·§ÏäºÍÁ÷ÌåÈÝÆ÷¡£

Ò×ÓÃʹÓÃ
¿ìËÙÈÝÒ×ÉèÖñá£ÊäÈë×¢ÉäÆ÷µÄÖ±¾¶»òʹÓÃÄÚ²¿×¢ÉäÆ÷ÊäÈë²éÕÒ±í×Ô¶¯×¢ÉäÆ÷Ö±¾¶µÄ×¢ÉäÆ÷ÖÆÔìÉ̺ʹóС¡£Ñ¡Ôñģʽ£¨Á¬Ðø»òÌå»ý·ÖÅ䣩ºÍËٶȡ£

Ìص㣺
ͨÓÃÊäÈëµçÔ´¹©Ó¦Æ÷£ºÎÞÐè¸ü»»ACÏß¿ª¹Ø£¬±£ÏÕË¿£¬»òµçÏß¡£
·ÇÒ×ʧÐÔÄڴ棺´æ´¢ËùÓÐÊý¾ÝºÍ³ÌÐòÐòÁС£
ʧËÙ¼ì²â£ºÒ»¸ö¹â¼ì²âÆ÷ÑéÖ¤µç»úÔ˶¯¡£
ÊÓ¾õ/Ìý¾õ¾¯±¨

µçÔ´Ñ¡Ôñ£º
RS-232 Á¬½Ó:
TTLÁ¬½Ó£º
²Ù×÷ģʽ
³¬¸ßѹ¿É±à³Ì¾«ÃÜ×¢Éä±Ã 
 

¼¼Êõ²ÎÊý
702200
ÀàÐÍ
Microprocessor single syringe, infuse/withdraw, programmable from keypad
±Ã½á¹¹
Standard
±Ã¹¦ÄÜ
Infuse/Withdraw, programmable
*СÁ÷ËÙ
0.0001 µl/hr
*´óÁ÷ËÙ
220.82 ml/min
×¢ÉäÆ÷ÊýÁ¿
1
×¢ÉäÆ÷¼ÜÀàÐÍ
Standard Rack
×¢ÉäÆ÷*С³ß´ç
0.5 µl
×¢ÉäÆ÷*´ó³ß´ç
140 ml
ƽ¾ùÖ±ÏßÍÆÁ¦
200 lbs (fluid pressure > 1,800 psi with an 8 ml stainless steel syringe
ѹÁ¦
High
ͨÐŵȼ¶
3
ͨÐÅ
RS-232, TTL, programmable
**¶È
0.35 %
¸´ÏÖÐÔ
0.05 %
·ÇÒ×ʧÐÔ´æ´¢Æ÷
´æ´¢ËùÒÔÉèÖÃ
RS-232
RJ11-4 Connector
TTL
9-pin connector D-sub.
Âí´ï
1/2 to 1/32 microstepping, microprocessor controlled, 1.8° step angle motor
µ¼ÏòÂݸËÿתһȦµç»úÇ°»ú²½Êý
800 at 1/2 stepping to 12,800 at 1/32 stepping
*С²½ËÙ
27.3 sec/step
*´ó²½ËÙ
416.7 µsec/step
²½ËÙ·Ö±æÂÊ
0.082 µm/step
ÍƽøÆ÷Òƶ¯*СËÙ¶È
0.18 µm/min
ÍƽøÆ÷Òƶ¯*´óËÙ¶È
190.676 mm/min
ÏÔʾ
Fluorescent, 2-line, 40 character
ÊäÈ빦ÂÊ
0.75 A, 75 W
µçѹ·¶Î§
100 to 240 VAC, 50/60 Hz
¸ß¶È
17 cm
¿í¶È
23 cm
Éî¶È
29 cm
¾»ÖØ
6.4 kg

 
 


4400 ³¬¸ßѹ¿É±à³Ì¾«ÃÜ×¢Éä±Ã


The PHD 4400 Hpsi Programmable Syringe Pump is a single syringe infuse-withdraw pump equipped with all the functions of the PHD 22/2000 Programmable Model, but with a high-power stepper motor to provide up to 200 lbs. of linear force.

Pressure and Speed

The PHD 4400 Hpsi can deliver up to 220.82 ml/min with a single 140 ml syringe. Maximum pressure is dependent on syringe size. For stainless steel syringes, see page A70.

Flexibility and Easy Programmability

?Two standard infusion modes (continuous or volume dispense)

?Internal programmable pump control in all models

?In Program Mode, complex infuse and withdraw applications can be easily created, stored in the pumps nonvolatile memory and recalled for later use.

?Autofill Mode provides continuous delivery when the pump is used in conjunction with either a standard or high pressure valve box and a fluid reservoir.

Ease of Use

Setting the pump is quick and easy. Input the diameter of the syringe or use the internal Syringe Lookup Table to automatically input the syringe diameter based on the syringe manufacturer and size. Select a mode (continuous delivery or volume dispense) and a rate and you are ready to go.

Features

Universal Input Power Supply: No need to change AC line switches, fuses, or wires.

Nonvolatile Memory: Stores all operational data and program sequences.

Stall Detection: An optical detector verifies motor movement. Stalls due to jamming or excessive back pressure are reported.

Visual/Audible Alarms

Power-Up Options: Powers-up in Standby or Running Mode after power interruption.

RS-232 Connections: Allows daisy-chaining of multiple pumps for remote control. Also allows for scale and printer connections.

TTL Connections: Allows for synchronizing pump with external devices, controlling an external valve, changing direction of travel, etc.

Modes of Operation

Pump Runs continuously in the infuse or refill directions until stopped.

Volume Runs until specified volume has been pumped or refilled.

Program Pump operates according to specified sequence of instructions. (Note: All modes

interact with Autofill feature.)

Specifications

Accuracy

?.35%

Reproducibility

?.05%

Syringes

0.5 µl min/140 ml max single syringe

Flow Rate:

 

Minimum

0.0001 µl/hr (with 0.5 µl syringe)

Maximum

220.82 ml/min (with 140 ml syringe)

Calibration

Automatic

Display

2-line, 40 character fluorescent

Memory

Nonvolatile (stores all settings)

Interface

RS-232 multiplexed dual bidirectional ports

Connectors:

 

RS-232

RJ-11 4-conductor telephone plug

TTL

9-pin D-SUB connector

Linear Force

>200 lbs (91 kg)*

Fluid Pressure*

>1,800 psi with an 8 ml stainless steel syringe, for example

Drive:

 

Motor

1.8?stepper

Control

Microprocessor (from 1/2 to 1/32 microstepping)

Step/Rev.

From 800 to 12,800

Step Rate:

 

Minimum

27.3 sec/step

Maximum

416.7 µsec/step

Pusher Travel Rate:

 

Minimum

0.18 µm/min

Maximum

190.676 mm/min

Resolution

0.082 µm/step

Power

100-240 VAC, 50/60 Hz, 75 W, 0.75 A fuse

Dimensions, H x W x D

17 x 23 x 29 cm (6.7 x 9.0 x 11.4 in)

Weight

6.4 kg (14 lbs)

Remote Cable

9.1 m (30 ft) Length

* For work range, refer to User’s Manual for details.

±¾²úÆ·Ìṩ1ÄêÈ«Ãâ·ÑÊÛºó·þÎñ£¬°üÀ¨²úÆ·½éÉÜ¡¢ËÍ»õ¡¢°²×°¡¢µ÷ÊÔ¡¢Î¬ÐÞ¡¢¼¼ÊõÅàѵ¡¢****µÈ£¨Óë¿Í»§ÓÐÌØÊâÔ¼¶¨µÄ°´ÕÕÔ¼¶¨Ö´ÐУ©¡£
 
¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´µÄ±ê×¼·þÎñÁ÷³ÌΪ£º
 
l ÒÇÆ÷ÍêºÃÎÞËðÔËË͵½¿Í»§´¦
l ×¨Òµ¹¤³Ìʦ½Óµ½Åɹ¤µ¥£¬Óë¿Í»§Ö÷¶¯ÁªÏµ£ºÁ˽â¿Í»§ÏÖ³¡Çé¿ö¡¢¸æÖª¿Í»§ÐèҪ׼±¸µÄ±ØÒªÌõ¼þ¡¢Óë¿Í»§Ô¼¶¨°²×°Åàѵʱ¼ä
l ×¨Òµ¹¤³Ìʦµ½´ï¿Í»§ÏÖ³¡£¬Ïò¿Í»§Ö÷¶¯³öʾ¹¤×÷Ö¤¼þºÍ°²×°ÅàѵִÕÕ
l ×¨Òµ¹¤³Ìʦ¼ì²é»õÎï°ü×°Çé¿ö£¬°´ÕÕºÏͬÓë¿Í»§Ò»ÆðÇåµã»õÎï
l ÔÚ¿Í»§Ö¸¶¨µÄ·ûºÏÒÇÆ÷ÔËÐÐÌõ¼þµÄλÖ㬰²×°ÒÇÆ÷
l ²âÊÔµçѹ²¢¿ª»úÊÔÔËÐÐÒÇÆ÷
l Ïò¿Í»§½éÉܸ÷¸öÓ²¼þ×é³É²¿·Ö
l Ïò¿Í»§½éÉÜÒÇÆ÷µÄÓ²¼þ²Ù×÷
l Åàѵ¿Í»§Ê¹ÓÃÈí¼þ
l Ïò¿Í»§¸æÖªÒÇÆ÷ÔËÐÐ×¢ÒâÊÂÏîÓë±£Ñø¹æÔò
l »Ø´ð¿Í»§ÒÉÎÊ
l Åãͬ¿Í»§ÊÔÓÃÒÇÆ÷
l Óë¿Í»§Ò»ÆðÇ©Êð¹¤×÷±¨¸æ¡¢±£ÐÞµ¥ÓëÑéÊÕ±¨¸æ
l ½«·þÎñÁªÏµ±êÅÆÌùÔÚÐÑĿλÖ㬱ãÓÚ¿Í»§ÁªÏµ¹¤³Ìʦ
l 2-4Öܺó»Ø·Ã¿Í»§£¬²¢½â´ð¿Í»§Ìá³öµÄÔÚʹÓÃÖгöÏÖµÄÎÊÌâ
 
 
×ðÖØ¿Í»§£¬Àí½â¿Í»§£¬Ò»Çдӿͻ§½Ç¶È³ö·¢£¬³ÖÐøÌṩ³¬Ô½¿Í»§ÆÚÍûµÄ²úÆ·Óë·þÎñ£¬×ö¿Í»§ÃÇÓÀÔ¶µÄ»ï°é¡£ÕâÊǾ¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´Ò»Ö±¼á³ÖºÍ³«µ¼µÄ·þÎñÀíÄî¡£
 
l ÐÄÖÐÓÀÔ¶Ê×ÏÈÏëµ½µÄÊÇ¿Í»§£¬¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´Ìáµ½µÄÖÊÁ¿²»½ö½öÖ¸²úÆ·µÄÄÚÔÚÖÊÁ¿£¬»¹°üÀ¨²úÆ·µÄ°ü×°ÖÊÁ¿¡¢·þÎñÖÊÁ¿µÈһϵÁÐÒòËØ¡£Òò´Ë±ØÐë**µØ¡¢*´óÏ޶ȵØÂú×ã¿Í»§µÄÐèÇó¡£
l Ó¦Õ¾ÔÚ¿Í»§µÄÁ¢³¡£¬¶ø²»ÊÇÕ¾ÔÚ¹«Ë¾µÄÁ¢³¡ÉÏÈ¥Ñо¿¡¢Éè¼ÆºÍ¸Ä½ø·þÎñ¡£
l ÍêÉÆ·þÎñϵͳ£¬¼ÓÇ¿ÊÛÇ°¡¢ÊÛÖС¢ÊÛºó·þÎñ£¬¶Ô¿Í»§ÔÚʹÓÃÖгöÏֵĸ÷ÖÖÎÊÌ⼰ʱ°ïÖú½â¾ö£¬Ê¹¿Í»§¸Ðµ½¼«´ó·½±ã¡£
l ¸ß¶ÈÖØÊÓ¿Í»§Òâ¼û£¬°Ñ´¦Àí¿Í»§µÄÒâ¼û×÷Ϊʹ¹Ë¿ÍÂúÒâµÄÖØÒªÒ»»·¡£
l 5SÀíÄ“5S”ÊÇÖ¸“΢Ц£¨SMILE£©¡¢Ñ¸ËÙ£¨SPEED£©¡¢³Ïʵ£¨SINCERITY£©¡¢ÁéÇÉ£¨SMART£©¡¢Ñо¿£¨STUDY£©”Îå¸ö´ÊÓïÓ¢ÎÄÊ××ÖĸµÄËõд¡£“5S”ÀíÄîÊÇ*¾ß´ú±íÐԵķþÎñÎÄ»¯**£¬²»½ö¾ßÓÐÈËÐÔ»¯Ê®×ãµÄʱ´úÌص㣬»¹¾ß±¸Ï൱µÄ¿É²Ù×÷ÐÔ¡£
 
 
Æ·ÖʳÐŵ
ÔËËÍ˵Ã÷
ÊÛºó·þÎñ
·þÎñÀíÄî
ÁªÏµ¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´
ʵÎïÅÄÕÕÁ¦ÇóÕæʵ
È«ÐÂÔ­³§**½ø¿Ú
²úÆ·¹¦ÄÜÈçʵÃèÊö
¹ú¼Êרҵ»õÔË¿ìµÝ·þÎñ
Ô˱£·ÑÈçʵÊÕÈ¡¼«ÓÅ»Ý
»õÆڶ̰ü×°ºñʵ¼«**
רҵ¹¤³ÌʦÉÏÃÅ°²×°
Ò¼ÄêÈ«Ãâ·Ñ±£ÐÞ·þÎñ
365ÌìÉÏÃÅÅàѵ·þÎñ
·þÎñרҵ¡¢ÒµÎñºñµÀ
×ðÖØ¿Í»§¡¢Àí½â¿Í»§
ÖµµÃÄúÐÅÀµµÄ·þÎñÉÌ
µç»°£º010-51650521
´«Õ棺010-51650521
Óʼþ:info@naturegene.com
 
 
¾¢±¬ÌåÓýNBAÖ±²¥Ãâ·Ñ¹Û¿´¿Æ¼¼×Ü´ú²úÆ·£¬ÇëÁªÏµ£¬

010-51650520

info@naturegene.com
±êÌ⣺
ÄÚÈÝ£º
ÁªÏµÈË£º
ÁªÏµµç»°£º
Email£º
¹«Ë¾Ãû³Æ£º
ÁªÏµµØÖ·£º
 
 
×¢£º1.¿ÉÒÔʹÓÿì½Ý¼üAlt+S»òCtrl+Enter·¢ËÍÐÅÏ¢!
2.ÈçÓбØÒª,ÇëÄúÁôÏÂÄúµÄÏêϸÁªÏµ·½Ê½!
sitemap¡¢ÍøÕ¾µØͼ